{"id":18198,"date":"2025-10-31T12:04:56","date_gmt":"2025-10-31T11:04:56","guid":{"rendered":"https:\/\/www.lunatone.com\/?p=18198"},"modified":"2025-10-31T12:04:57","modified_gmt":"2025-10-31T11:04:57","slug":"new-dali-2-phase-cut-sensor","status":"publish","type":"post","link":"https:\/\/www.lunatone.com\/en\/2025\/10\/31\/new-dali-2-phase-cut-sensor\/","title":{"rendered":"New: DALI-2 Phase Cut Sensor"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_empty_space height=&#8221;40px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;]<\/p>\n<div class=\"\">\n<div class=\"\">\n<div class=\"\">\n<p data-start=\"0\" data-end=\"322\">The compact interface module converts 0\u2013230V PhaseCut control signals into DALI dim levels.<br data-start=\"95\" data-end=\"98\" \/>The incoming 0\u2013230V voltage is broadcasted as a dimming value to the DALI subnet. Changes in the input voltage greater than 1% serve as event triggers. A minimum load is required for operation of the control device.<\/p>\n<p data-start=\"324\" data-end=\"522\" data-is-last-node=\"\" data-is-only-node=\"\">The version with integrated DALI Power Supply (Art. Nr. 86468411-PS), provides 30mA for the subnet (up to 10 DALI ballasts).<br data-start=\"457\" data-end=\"460\" \/>Expansion to up to 64 loads is possible using a DALI Expander.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][vc_single_image image=&#8221;7071&#8243; img_size=&#8221;119&#215;35&#8243;][vc_column_text]<\/p>\n<hr \/>\n<p>[\/vc_column_text][vc_column_text css=&#8221;&#8221;]Product link: <span style=\"color: #008080;\"><a style=\"color: #008080;\" href=\"https:\/\/www.lunatone.com\/en\/product\/dali-2-phase-cut-sensor\/\">https:\/\/www.lunatone.com\/en\/product\/dali-2-phase-cut-sensor\/<\/a><\/span><br \/>\nDatasheet: <span style=\"color: #008080;\"><a style=\"color: #008080;\" href=\"https:\/\/www.lunatone.com\/wp-content\/uploads\/2025\/10\/86468411_DALI-2-Phase-Cut-Sensor_EN_D0138.pdf\">https:\/\/www.lunatone.com\/wp-content\/uploads\/2025\/10\/86468411_DALI-2-Phase-Cut-Sensor_EN_D0138.pdf<\/a><\/span>[\/vc_column_text][vc_column_text]<\/p>\n<hr \/>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;10px&#8221;][vc_single_image image=&#8221;18155&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css=&#8221;&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text css=&#8221;&#8221;]<\/p>\n<div class=\"page\" title=\"Page 4\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Example Installation DALI-2 Phase Cut Sensor:<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;18113&#8243; img_size=&#8221;full&#8221; css=&#8221;&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text css=&#8221;&#8221;]<\/p>\n<div class=\"page\" title=\"Page 4\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Example Installation DALI-2 Phase Cut Sensor with integrated DALI Power Supply of 30mA:<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;18115&#8243; img_size=&#8221;full&#8221; css=&#8221;&#8221;][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_empty_space height=&#8221;40px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;] The compact interface module converts 0\u2013230V PhaseCut control signals into DALI dim levels.The incoming 0\u2013230V voltage is broadcasted as a dimming value to the DALI subnet. Changes in the input voltage greater than 1% serve as event triggers. A minimum load is required for operation of the control device. The version [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":18174,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[68],"tags":[],"class_list":["post-18198","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/posts\/18198","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/comments?post=18198"}],"version-history":[{"count":3,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/posts\/18198\/revisions"}],"predecessor-version":[{"id":18217,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/posts\/18198\/revisions\/18217"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/media\/18174"}],"wp:attachment":[{"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/media?parent=18198"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/categories?post=18198"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/tags?post=18198"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}