{"id":19185,"date":"2026-04-02T10:21:16","date_gmt":"2026-04-02T08:21:16","guid":{"rendered":"https:\/\/www.lunatone.com\/?p=19185"},"modified":"2026-04-02T11:37:11","modified_gmt":"2026-04-02T09:37:11","slug":"new-dali-2-rm25","status":"publish","type":"post","link":"https:\/\/www.lunatone.com\/en\/2026\/04\/02\/new-dali-2-rm25\/","title":{"rendered":"New: DALI-2 RM25"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_empty_space height=&#8221;40px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;]<\/p>\n<div class=\"\">\n<div class=\"\">\n<div class=\"\">\n<div class=\"\">The DALI RM25 HS and DE provide a relay contact controllable via the DALI bus for inrush currents up to 1000A. In this way, loads without a DALI input can be easily integrated into a DALI circuit. Permanent loads up to 4000VA can be switched via DALI commands. The purposeful switching in voltage zero crossings, enables an increase of the device lifetime. Power-up mode and system-failure settings can be configured using the DALI Cockpit PC Software.<\/div>\n<div class=\"\">zero cross switching, integrated current limiter<\/div>\n<div class=\"\">1 normally open<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][vc_single_image image=&#8221;7071&#8243; img_size=&#8221;119&#215;35&#8243;][vc_column_text]<\/p>\n<hr \/>\n<p>[\/vc_column_text][vc_column_text css=&#8221;&#8221;]Product link version for DIN Rail:<span style=\"color: #008080;\"><a style=\"color: #008080;\" href=\"https:\/\/www.lunatone.com\/en\/product\/dali-2-rm25-hs\/\"> https:\/\/www.lunatone.com\/en\/product\/dali-2-rm25-hs\/<\/a><\/span><br \/>\nProduct link version for remote ceiling installation: <span style=\"color: #008080;\"><a style=\"color: #008080;\" href=\"https:\/\/www.lunatone.com\/en\/product\/dali-2-rm25-de\/\">https:\/\/www.lunatone.com\/en\/product\/dali-2-rm25-de\/<\/a><\/span><br \/>\nDatenblatt:<span style=\"color: #008080;\"><a style=\"color: #008080;\" href=\"https:\/\/www.lunatone.com\/wp-content\/uploads\/2024\/06\/86456944_86456203_DALI-2_RM8_RM16_RM25_EN_D0130.pdf\"> https:\/\/www.lunatone.com\/wp-content\/uploads\/2024\/06\/86456944_86456203_DALI-2_RM8_RM16_RM25_EN_D0130.pdf<\/a><\/span>[\/vc_column_text][vc_column_text]<\/p>\n<hr \/>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;10px&#8221;][vc_single_image image=&#8221;19183&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css=&#8221;&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text css=&#8221;&#8221;]<\/p>\n<div class=\"page\" title=\"Page 4\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Application example:<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;18954&#8243; img_size=&#8221;full&#8221; css=&#8221;&#8221;][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_empty_space height=&#8221;40px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;] The DALI RM25 HS and DE provide a relay contact controllable via the DALI bus for inrush currents up to 1000A. In this way, loads without a DALI input can be easily integrated into a DALI circuit. Permanent loads up to 4000VA can be switched via DALI commands. The purposeful switching [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":19188,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[68],"tags":[],"class_list":["post-19185","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/posts\/19185","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/comments?post=19185"}],"version-history":[{"count":4,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/posts\/19185\/revisions"}],"predecessor-version":[{"id":19197,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/posts\/19185\/revisions\/19197"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/media\/19188"}],"wp:attachment":[{"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/media?parent=19185"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/categories?post=19185"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lunatone.com\/en\/wp-json\/wp\/v2\/tags?post=19185"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}